Specifications

114 Part Number 80-01111-9 7/10
Safety Limit #2
Harvest time exceeds 3.5 minutes for 6
Consecutive harvest cycles.
Possible Cause Checklist
Improper installation
Refer to “Installation and Visual Inspection
Checklist” on page 104.
Water System
Water area (evaporator) dirty
Dirty/defective water dump valve
Vent tube not installed on water outlet drain
Water freezing behind evaporator
Plastic extrusions and gaskets not securely
mounted to the evaporator
Low water pressure (20 psig min.)
Loss of water from sump area
Clogged water distribution tube
Dirty/defective float valve
Defective water pump
Electrical system
Ice thickness probe out of adjustment
Ice thickness probe dirty
Bin switch defective
Premature harvest
Refrigeration system
Non-Manitowoc components
Improper refrigerant charge
Defective hot gas valve
TXV flooding (check bulb mounting)
Defective fan cycling control