Specifications

Part Number STH042 3/14 73
Safety Limit #2
Harvest time exceeds 3.5 minutes for 100
Consecutive harvest cycles.
Possible Cause Checklist
Improper installation
Refer to “Installation/Visual Inspection Checklist”
on page 64.
Water System
Water area (evaporator) dirty
Dirty/defective water dump valve
Vent tube not installed on water outlet drain
Water freezing behind evaporator
Plastic extrusions and gaskets not securely
mounted to the evaporator
Low water pressure (20 psig min.)
Loss of water from sump area
Clogged water distribution tube
Dirty/defective water inlet valve
Defective water pump
Electrical system
Water inlet valve defective
Bin switch defective
Premature harvest
Refrigeration system
Non-Manitowoc components
Improper refrigerant charge
Defective harvest valve
TXV flooding (check bulb mounting)
Defective fan cycling control