Specifications
88 Part Number STH12 9/10
ERROR CODES E1, E2, & E3 FLOWCHART
EI
YES
NO
NORMALLY CAUSED
BY WATER
PRESSURE <5 PSI
FOR 5 SECONDS
MUST STAY ABOVE
10 PSI TO CORRECT
E3 E4 E5 E6 E7 E8 E9
E2
NO
YES
NO
NO
YES
YES/END
NOTE: THAT
ALL CARB
MOTORS AND
ALL CIRC
MOTORS WILL
GO OFF, WITH
THIS
ERRORCOMPR
ESSOR AND
AGITATOR
STAY ON
NORMALLY CAUSED
BY CO2 PRESSURE
<10 PSI FOR 5
SECONDS MUST
STAY ABOVE 15 PSI
TO CORRECT
NORMALLY
CAUSED BY
WATER LEVEL IN
WATER BATH
BELOW PROBE
CONDUCTORS
GO INTO PROGRAM
MODE 1 PRESSURE
READOUT “P000”
GO INTO PROGRAM
MODE 1 PRESSURE
READOUT “P000”
PRESS CARB A
BUTTON TO VERIFY
WATER
PRESSURE“PXXX”
DISPLAY
PRESSURE
>15 PSI
PRESS CARB B
BUTTON TO VERIFY
CO2 PRESSURE
“PXXX” PSI
DISPLAY
PRESSURE
>20PSI
VERIFY WATER
LEVEL ABOVE
PROBE TIPS
ADD WATER TO
WATER BATH
ABOVE LEVEL OF
PROBE TIPS
GO INTO PROGRAM
MODE 1
CONDUCTIVITY“C000”
E3 ERROR
GOES OFF
PRESS CIRC A BUTTON
TO VERIFY
CONDUCTIVITY“CL_X”