Specifications
Part Number STH12 9/10 87
Troubleshooting
Electronic Refrigeration Control (ERC)
Model Error Codes
• Error codes will interrupt the temperature display
and stay active until the error is corrected.
• If multiple errors are present, the errors will rotate
and display every 5 seconds.
• Resetting errors — After correcting the problem,
the respective switch for the error must be cycled
OFF and then ON to reset.
• Disconnecting and reconnecting power will erase
all errors.
Error
Code
Error Cause
E1 Low Water Supply Pressure Lower than 5 psi for 5 Seconds
E2 Low CO
2
Pressure Lower than 10 psi for 5 Seconds
E3 Low Water Level – Water
Bath
Must Cover Top of Evaporator
E4 High Water Bath Temperature Water Bath Temperature Greater
Than 45°F
E5 High Water Supply Pressure Water Pressure Greater than
75 psi
E6 High Refrigeration
Temperature
Discharge Line Temperature
Greater than 190°F
E7 High Ice Bank Size Ice Contacting Center Ice Bank
Probe
E8 Long Carb A Run Time Energized for 7 Continuous
Minutes
E9 Long Carb B Run Time Energized for 7 Continuous
Minutes