Specifications

86 Part Number STH12 9/10
“C000”(CONDUCTIVITY)
PRESS COMP/AGIT
SWITCH TO SHOW ICE
BANK PROBE
“CC11” = NO ICE
COMPRESSOR ON
“CC10”= ICE ON LOW
SENSOR COMPRESSOR
OFF
“CC00” = ICE BANK TOO
LARGE (E7)
PRESS CARB A SWITCH
TO SHOW LLC PROBE
“CA00” = NO WATER
CARB A MOTOR ON
“CA01”= LOW SENSOR
IN WATER, MOTOR ON
“CA11” = LOW & HIGH
SENSOR IN WATER,
MOTOR OFF
REPEAT ABOVE FOR
CARB B SWITCH “CbXX”
PRES CIRC A SWITCH
TO SHOW WATER
LEVEL PROBE
“CL_1” = WATER
“CL_0” = LOW WATER
(E3)
PRESS COMP/AGIT
SWITCH, DISPLAY
SHOWS “---4”
INDICATING ERROR
CODES WILL BE
DISABLED UNTIL
NEXT POWER OFF/ON
SEQUENCE
“F000” (TEMPERATURE)
PRESS CARB A SWITCH
TO SHOW WATER BATH
TEMP
PRESS CIRC A SWITCH
TO SHOW
LIQUID LINE TEMP
PRESS CIRC B SWITCH
TO SHOW
SUCTION TEMP
“P000” (PRESSURE)
PRESS CARB A SWITCH
TO SHOW WATER
SUPPLY PRESSURE
PRESS CARB B
SWITCH TO SHOW CO2
PRESSURE
PRESS COMP/AGIT
SWITCH ONCE, DISPLAY
=”1XX3" WHERE XX= SET
POINT TEMPERATURE
(DEFAULT = “1273”)
(DIFFERENTIAL FIXED AT
ABOVE SET POINT)
PRESS CIRC A SWITCH
TO LOWER SET POINT
TEMPERATURE
PRESS CIRC B SWITCH
TO RAISE SET POINT
TEMPERATURE
NOTE:
SET POINT =
COMPRESSOR OFF
DIFFERENTIAL IS FIXED
AT 2°F ABOVE SET POINT
COMPRESSOR ON
PRESS CARB A SWITCH TO
CONVERT CARB A MOTOR
TO CIRC MOTOR
“-102”
PRESS CARB B SWITCH TO
CONVERT CARB B MOTOR
TO CIRC MOTOR
“-112”
PRESS PGM SWITCH
ONCE (1)
PRESS PGM SWITCH
ONCE (1)
TO CHANGE UNITS
WHEN “F000” PRESS
COMP/AGIT SWITCH
ONCE (1) TO CHANGE
TEMPERATURE UNITS
TO CENTIGRADE
“FC00”
WHEN “P000” PRESS
COMP/AGIT SWITCH
ONCE (1) TO CHANGE
PRESSURE UNITS TO
BAR
“Fb00”