Specifications

82 Part Number STH12 9/10
Program Mode 4
Temporarily cancel display of error codes. Cancelling
the error codes allows circulating glycol temperatures
to be displayed until the error can be corrected.
Press PGM button for 3 seconds — Display shows
0001.
Press PGM button three times — Display shows
0004 program mode 4.
Wait 3 seconds — Display shows -004 = All error
codes will be displayed during run mode.
Press COMP/AGIT button once — Display shows
---4 = error codes will not be displayed during run
mode.
NOTE: Disconnecting and reconnecting main power
will reset the control board to the factory setting -004 =
Error codes will be displayed in the run mode.
Equipment Setup Procedure (with ERC)
1. Ensure that all valve nozzles are attached to the
valves.
2. Observe pressure of CO
2
high pressure tank of
500 psi (34 bar) or more, or bulk CO
2
tank of
150 psi or more. Primary regulator set at 90 psi
(6 bar) and the secondary regulator set at 35 psi
(2.4 bar).
3. Observe the control panel to verify that all
pressure gauges are set at correct operating
pressures.
4. Check the syrup tanks or BIB to make sure a
sufficient number of tanks are connected in series
to satisfy business volume.
5. Clean syrup inlet and outlet quick disconnects at
the same time tanks are replaced. Rinse
disconnects in clean potable water.