Specifications
Part Number STH12 9/10 81
• Press and hold Carb B switch — Display will
indicate one of the following:
• Cb00 — Low and High Probes are open
(carbonator motor is energized)
• Cb11 — Low and High Probes are closed
(carbonator motor is de-energized)
• Cb01 — Low Probe closed (Motor will still be
on)
• Press and hold COMP/AGIT switch — Display will
indicate one of the following:
• CL 0 — Water level low
• CL 1
— Water level OK
Program Mode 2
Add circulation pumps C & D.
• Press PGM button for 3 seconds — Display shows
0001.
• Press PGM button — Display shows 0002
program mode 2.
• Wait 3 seconds — Display shows -002 = Factory
default setting.
• Pressing CIRC A button
energizes/de-energizes pump A
• Pressing CIRC B button
energizes/de-energizes pump B
• Program CIRC C — Press CARB A button –
Display shows -102 = Carb A button
energizes/de-energizes pump C
• Program CIRC D — Press CARB B button -
Display shows -012 = Carb B button
energizes/de-energizes pump D
Press and hold PGM switch for 3 seconds to save
settings and exit program mode.