Specifications
80 Part Number STH12 9/10
PGM Switch
• Used to enter and exit programming modes.
• Press PGM Switch F000 will display
• Press and hold Carb A switch — Display will
indicate Water Bath Temperature
• Press and hold Circ A switch — Display will
indicate Discharge Temperature
• Press and hold Circ B switch — Display will
indicate Suction Temperature
• Press PGM Switch P000 will display
• Press and hold Carb A switch — Display will
indicate Water Pressure
• Press and hold Carb B switch — Display will
indicate CO2 Pressure
Press and hold PGM switch for 3 seconds to save
settings and exit program mode.
Program Mode 1
To enter, press and hold switch for 3 seconds.
• 0001 will display indicating Mode 1
• Wait 3 seconds — C000 will display
• Press and hold Carb A switch — Display will
indicate one of the following:
• CA00 — Low and High Probes are open
(carbonator motor is energized)
• CA11 — Low and High Probes are closed
(carbonator motor is de-energized)
• CA01 — Low Probe closed (Motor will still be
on)