Specifications

Part Number STH12 9/10 77
PLACING THE SYRUP SYSTEM IN OPERATION
1. Open the CO
2
gas supply valve at CO
2
tanks or
bulk tank. Adjust the CO
2
pressure to 90 psi
(6.2 bar).
2. Open relief valve on top of the carbonator tank for
4 seconds to bleed off air in tank.
3. Verify the water supply to unit is on.
4. Press the switch labeled “Carb A” (and B if
applicable). Allow carbonator to run and cycle
OFF.
5. Press the switch labeled “CIRC A” (and “CIRC B”
if applicable).
6. Activate all vales until a smooth, continuous flow
or carbonated water and non-carbonated water
appear at the valves.
7. Allow at least 1 hour before proceeding to
calibration instructions. You may complete the
sanitizing instructions during this period.