Specifications
58 Part Number STH12 9/10
Sanitizing
BEVERAGE SYSTEM CLEANING
Sanitize the beverage system at initial start-up as well
as regularly scheduled cleaning. The drain pan must
be in place under soda valves, to carry away detergent
and sanitizing agents that will be flushed through
valves.
BAG-IN-BOX SYSTEM SANITATION
The procedure below is for the sanitation of one
syrup circuit at a time. Repeat to sanitize
additional circuits.
You will need the following items to clean and sanitize
the Bag-in-Box (BIB) beverage system:
• Three (3) clean buckets
• Plastic brush or soft cloth
• Mild detergent
• Unscented bleach (5% Na CL O) or
Commercial sanitizer
• Bag-In-Box bag connector
1. Prepare the following in the buckets:
• Bucket 1 — warm to hot tap water for rinsing.
• Bucket 2 — mild detergent and warm to hot
water.
! Warning
Flush sanitizing solution from syrup system.
Residual sanitizing solution left in system could
create a health hazard.
! Warning
When using cleaning fluids or chemicals, rubber
gloves and eye protection must be worn.