Specifications
Part Number STH12 9/10 53
• If pressure is low, inspect water filter cartridges to
ensure they are able to supply adequate water
pressure under normal system flow. Replace if
unable to provide minimum 40 psi (1.4 bar) under
load.
• Inspect syrup lines for proper flavor identification
labels. Replace labels if necessary.
• Disconnect syrup containers. Clean connector with
soap and warm water. Rinse with plain water and
reconnect to syrup containers.
• Inspect pressure setting at CO
2
high pressure
regulator. Verify proper 90 psi (6.3 bar) pressure
setting. Adjust if necessary.
• Inspect pressure setting at syrup pressure
regulators. Verify propter pressure setting. Adjust if
necessary.
• Inspect system for CO
2
leaks. Repair as required.