Specifications

Part Number STH12 9/10 51
Syrup supply
Daily (365 times per year)
Clean general area of syrup hookup with soap and
warm water. Rinse off all soap.
Every 4 months (3 times per year)
Inspect syrup lines for proper flavor identification
labels. Replace labels if necessary.
Disconnect syrup containers. Clean connector with
soap and warm water. Rinse with plain water and
reconnect to syrup containers.
CO
2
gas supply
Every 4 months (3 times per year)
Inspect pressure setting at CO
2
high pressure
regulator. Verify proper 90 psi (6.3 bar) pressure
setting. Adjust if necessary.
Inspect pressure setting at syrup pressure
regulators. Verify propter pressure setting. Adjust if
necessary.
Inspect system for CO
2
leaks, repair as required.
PERIODIC MAINTENANCE FOR SOFT DRINK
EQUIPMENT (LISTED BY SCHEDULED
FREQUENCY)
Daily (365 times per year)
Take temperature of finished drinks. Pour off the
first and take the temperature of the second drink.
The proper temperature of drinks must be 38°F
(4°C) or less.
Remove nozzles and diffusers from each
dispensing valve. Clean with soap and warm water
(not hot). Rinse with carbonated water and
reinstall.
Flush all dispenser drains. Pour hot water down
drains at closing.
Clean general area of syrup hookup with soap and
warm water. Rinse off all soap.
Every 4 months (3 times per year)
Using Brix cup and syrup separator, check for
proper carbonated water flows (standard flow: 5
oz. in 4 seconds, fast flow: 10 oz. in 4 seconds)