Specifications

42 Part Number STH12 9/10
5. Turn on the main water supply to the booster
assembly. Verify the booster is plugged in and
that the accumulator tank valve is open. (If the
system has an optional “Out-of-Syrup” device,
verify that it is unplugged.)
6. Verify the pump is running. Place the valve on the
right side of the pump box in the purge position
until all air bubbles have passed through the line.
Turn the valve back to “dispense”. Plug the
Out-of-Syrup device power cord into an
appropriate wall outlet at this time (if supplied).
NOTE: Verify that the pump box holding tank is full
before proceeding.
7. Turn on the circulator and carbonator. The
carbonator must run for approximately 1 to 3
minutes and shut off. The circulator must run
continuously. Verify that water is returning to the
water bath through the return bulk head fitting.
8. Go to the tower(s) and brix the valves. Using a
syrup separator and volume cup, adjust the flow
rate of the carbonated water to two fluid ounces
per second. Then, using the separator and a brix
cup, adjust the syrup flow rate for a ratio of
carbonated water to syrup to 5 to 1.
Important
Wait until a thin layer of ice has begun to form on
the evaporator before proceeding any further.