Specifications
38 Part Number STH12 9/10
Plumbing/Water Supply
PLUMBING POTABLE WATER
A 1" (2.54 cm) ID copper inlet water line equipped with
a 3/4" (1.905 cm) FPT adapter with shut-off must be
supplied by plumber at rear of equipment. Appropriate
floor drains must be provided within 6 ft (183 cm) of
each unit installed.
NOTE: The carbonator in this unit is provided with a
dual check valve type back-flow preventer, which
conforms to ASSE 1032. The Model 50M & 44M
vented backflow preventer conforms to ASSE 1022.
Potable water connections to the equipment must
comply with the basic plumbing code of the Building
Officials and Code Administrators International, Inc.
(BOCA) and the Food Service Sanitation Manual of
the Food and Drug Administration. Verify local
plumbing code requirements.
Model
Required
Water
Pressure
Drain
Connections
Water
Supply
2803 &
SC180
40 – 70 psig
(2.8 – 4.9 bar)
3/4" ID
within 6 ft (2 m)
3/8" ID
EVA Line
11M &
SC340
40 – 70 psig
(2.8 – 4.9 bar)
3/4" ID
within 6 ft (2 m)
3/8" ID
EVA Line
44M,
42M &
SC1000
40 – 70 psig
(2.8 – 4.9 bar)
3/4" ID
within 6 ft (2 m)
1/2" ID
EVA Line
50M 40 – 70 psig
(2.8 – 4.9 bar)
3/4" ID
within 6 ft (2 m)
1/2" ID
EVA Line
SC2000 40 – 70 psig
(2.8 – 4.9 bar)
3/4" ID
within 6 ft (2 m)
1/2" ID
EVA Line