Specifications

32 Part Number STH12 9/10
3. Connect the water manifold supply line, located
on the bulkhead panel in the motor compartment
to the main water supply. The main water supply
shut-off valve must remain in the OFF position. If
a water filter is to be installed, connect the line to
the outlet fitting of the filter. Plumb according to
applicable plumbing codes.
Drain Hose Connection
4. When a water cooled condenser is installed, a
copper supply line (not supplied with unit) must be
plumbed to the 3/8" (.965 cm) male flare fitting
installed in the water shut-off assembly. The
shut-off must be placed in the OFF position. A
copper drain line (not supplied) is to be connected
to the outlet fitting of the water cooled condenser
and routed to the floor drain.
Screw
Drain Hose
Bottom
of Unit
Bracket