Specifications

28 Part Number STH12 9/10
Safe Installation Dos and Don’ts
! Warning
Read the following warnings before beginning an
installation. Failure to do so may result in
possible death or serious injury.
Adhere to all National and Local Plumbing
and Electrical Safety Codes.
Turn OFF incoming electrical service
switches when servicing, installing, or
repairing equipment.
DO NOT throw or drop a CO
2
cylinder.
Secure the cylinder(s) in an upright position
with a chain.
DO NOT store CO
2
cylinders in temperature
above 125°F (51.7°C) near furnaces, radiator
or sources of heat.
!
Warning
DO NOT connect the CO
2
cylinder(s) directly to
the product container. Doing so will result in an
explosion causing possible death or injury. It is best
to connect the CO
2
cylinder(s) to a regulator(s).
! Warning
Carbon Dioxide (CO
2
) displaces oxygen. Exposure
to a high concentration of CO
2
gas causes tremors,
which are followed rapidly by loss of consciousness
and suffocation. If a CO
2
gas leak is suspected,
particularly in a small area, immediately ventilate the
area before repairing the leak. CO
2
lines and pumps
must not be installed in an enclosed space. An
enclosed space can be a cooler or small room or
closet. This may include convenience stores with
glass door self serve coolers. If you suspect CO
2
may build up in an area, venting of the BIB pumps
and/or CO
2
monitors must be utilized.