Specifications

230 Part Number STH12 9/10
CO
2
Gas and Compressed Air Circuit Diagram
Carbonator
Tank “B”
Legend
— Manual Shut-off Valve
— Check Valve, Ball
— Manual 3-way Ball
— Connection for
Carbonator
Tank “A”
Sugar Free Line & Disconnect
Sugar Base Lines & Disconnects
Sugar Base Lines & Disconnects
Optional
Air/CO
2
Change-
over
Valve
Optional
CO
2
Change-over Valve
AB
Optional
Air Compressor
Optional Bulk
CO
2
Tank Set at
90-100 psi (6.2-6.9 bar)
Optional
CO
2
Tank
“A”
Optional
CO
2
Tank
“B”
Pressure Switch
“ON” = 70 psi (4.8 bar)
“OFF” = 90 psi (6.2 bar)
Shake
Machine
CO
2
Shut-off to
Carbonator Tank
Medium Pressure Regulator
Set at 60 psi (4.1 bar)
Low Pressure
Regulator
Set at 15 psi
(1 bar)
Shake Machine
Shut-off Valve
Optional CO
2
Regulators
Set at 90-100 psi
(6.2-6.9 bar)