144 Part Number STH12 9/10
Back-flow Preventer Maintenance
The integral carbonator in this unit is equipped with a
back-flow preventer designed to protect the potable
water supply from CO
2
contamination.
1. Shut OFF power to unit.
2. Shut OFF potable water supply to unit. Do not
shut OFF CO
2
supply.
3. Remove top cover panel of unit and disconnect
inlet fitting from back-flow preventer.
NOTE: The carbonator tank is still pressurized.
4. Observe inlet of backflow preventer #1 check for
any discharge. If there is no discharge, #1 check
is OK. Proceed to step 5. If there is discharge,
proceed to step 6.
5. Disconnect and carefully remove #1 check
assembly. Avoid losing any internal parts.
6. Observe inlet of #2 check for any discharge. If
there is no discharge, #2 check is OK. Proceed to
step 7. If there is discharge, proceed to step 5.
7. Shut OFF CO
2
supply and relieve pressure from
carbonator tank.
8. Remove back-flow preventer and install new
backflow preventer. Turn ON CO
2
supply and
check for leaks.
9. Check water supply strainer upstream of backflow
preventer. Clean out and/or replace as required.
10. Reconnect water lines and turn water supply ON.
11. Turn ON power to unit.
Important
The back-flow preventer must be checked at
least once every year to confirm that it is
functioning properly.