Specifications

142 Part Number STH12 9/10
J-16 Station and Sizes:
#1 Stop/Fill
#2 Large
#3 Medium
#4 Small
#5 Valve 6
#6 Valve 5
#7 Valve 4
#8 Valve 3
#9 Valve 2
#10 Valve 1
#11 Blank
#12 Extra Large
J-18 Stations
#1 Valve 7
#2 Valve 8
J-19 Stations and Sizes:
#1 Blank
#2 Valve 2 or 4 Flavor 1
#3 Valve 2 or 4 Flavor 2
#4 No wire
#5 Kid Size (Smallest)
Use a jumper wire to make these connections to
determine if timer is functioning properly.
1. Jump pin 1 on J-16 to pin 5, 6, 7, 8, 9, 10, and
pins 1 and 2 on J-18. Appropriate valve should
energize as long as pins are jumped.
2. Jump pin 12 on J-16 to 5, 6, 7, 8, 9, 10, and pins 1
and 2 on J-18. Valves should pour Extra Large.
3. Jump pin 2 on J-16 to 5, 6, 7, 8, 9, 10, and pins 1
and 2 on J-18. Valves should pour Large.
4. Jump pin 3 on J-16 to 5, 6, 7, 8, 9, 10, and pins 1
and 2 on J-18. Valves should pour Medium.
5. Jump pin 4 on J-16 to 5, 6, 7, 8, 9, 10, and pins 1
and 2 on J-18. Valves should pour Small.
6. Jump pin 5 on J-19 to J-16 pins 5, 6, 7, 8, 9, 10,
and pins 1 and 2 on J-18. Valves should pour Kid
Size.