Specifications

Part Number STH12 9/10 137
FEATURES OF THE NEW MPC84A
Can control up to 8 stations (valves).
Hardware isolation and zero switching to minimize
electrical problems.
Software improvements to noise.
CALIBRATION INSTRUCTIONS
(same as MPC64A)
1. To enter calibrate mode, press calibrate switch
three times in less than three seconds, and red
calibrate light will illuminate.
2. Place volume cup under nozzle of the valve to be
calibrated.
3. Press appropriate size switch and fill volume cup
to a point just short of the calibration mark on the
volume cup.
4. Let foam settle, jog size switch until liquid reaches
the appropriate calibration mark on the volume
cup.
5. To calibrate additional sizes, repeat steps 2 thru 4.
Special Features when in the Calibrate Mode
To obtain an accurate 4.0 seconds pour from any
valve, press its associated STOP-FILL switch
once.
To adjust all stations for the same size times, press
any station STOP-FILL switch twice in less than
two seconds, then repeat steps 2 thru 4 at this
station. The resulting times will be copied to all
stations when calibrate mode is exited.
6. To exit the calibrate mode, press calibrate switch
once and red calibrate light will go out.
Important
Use this mode, one size adjusts all, only for an
emergency (no time to adjust at all) and
temporarily. Each valve flow rate, ratio, and flow
regulators would have to be perfectly identical for
each valve to duplicate the same volume in the
same portion time.