Specifications
132 Part Number STH12 9/10
J-16 Station & Sizes
Revision May 28, 2003
#1 Stop/Fill
#2 Large
#3 Medium
#4 Small
#5 Valve 6 (or nothing on a 5 Valve tower)
#6 Valve 5
#7 Valve 4
#8 Valve 3
#9 Valve 2
#10 Valve 1
#11 Blank
#12 Extra Large
Use a jumper wire to make these connections to
determine if timer is functioning properly.
A. Jump pin 1 to pin 5,6,7,8,9,10. Appropriate
Valve should energize as long as pins are
jumped.
B. Jump pin 12 to pin 5,6,7,8,9,10. Valves
should pour EXTRA LARGE.
C. Jump pin 2 to pin 5,6,7,8,9,10. Valves should
pour LARGE.
D. Jump pin 3 to pin 5,6,7,8,9,10. Valve should
pour MEDIUM.
E. Jump pin 4 to pin 5,6.7,8,9,10. Valves should
pour SMALL.
J-17 CALIBRATION BUTTON & LIGHT
If microprocessor does not go into calibration, remove
connector at J-17. With jumper wire, jump 1st and 2nd
pins on left 3 times in less than 3 seconds. Replace
connector. Calibration light should be on
(microprocessor will be in the calibration mode). White
& White = calibration button. Red & Black = calibration
light. If CAL light does not come on LED is burned out
— replace keyboard.