Specifications

130 Part Number STH12 9/10
Problem
Probable
Cause
Solution
Drink too warm. Refrigeration
switch OFF.
Turn ON refrigeration switch.
Condenser dirty. Have condenser cleaned.
Condenser
obstructed.
Remove any objects blocking the air
flow in or out of the unit.
Circulator
switch OFF.
Turn ON circulator switch and allow
time for drinks to cool.
Note: If service is required, you can
continue to dispense cold drinks by
completing following this procedure.
1. Turn OFF the compressor switch
and agitator switch.
2. Drain the water from the water
bath. Reinstall the grey plastic
over-flow pipe.
3. Fill water bath with ice from the ice
machine.
4. Monitor frequently. Refill as
needed.
Not enough
carbonation.
CO
2
Shut-off
Valve OFF.
Open Shut-off Valve.
CO
2
cylinder
empty.
Switch over to a new cylinder and
dispense carbonated water until
carbonation returns.
Product foaming. Dirty or sanitizer
soaked.
Clean or replace nozzles.
Warm drinks. See “Drink too warm” under Problem
above.
No syrup
dispensed.
Empty syrup
container.
Replace syrup container.
Air Compressor
is OFF.
Turn ON and plug-in the Air
Compressor.
Change-over
valve centered.
Position switch totally on either air or
CO
2
.
No carbonated
water dispensed.
Carbonator
turned OFF.
Turn ON carbonator switch.
Water supply
turned OFF.
Turn ON water to the system.
Product has an off
taste.
Dirty nozzles. Clean or replace nozzles.
Out of date
syrup.
Replace with fresh syrup.
Saturated water
filters.
Replace water filters.