No carbonated water or insufficient carbonated water in finished drink
Section 5: Dispensing Valve and Tower (continued)
Qualifier Probable Cause Corrective Action
No Carbonated Water
only at one dispensing
valve.
Carbonated water Shut-off
Valve closed or partially
closed.
Mounting Block restricted.
Flow Control our of adjust-
ment or inoperative.
Valve Port restricted.
Seat swollen.
Solenoid Coil defective.
Carbonated Water Switch
defective (black).
Remove top cover from Dispensing valve or
Tower. Locate Carbonated Water Shut-off Valve
on left hand side of Dispensing valve. Verify
Shut-off Valve is turned fully open.
Remove Dispensing valve from Mounting Block.
Place cup over Carbonated Water outlet on
Mounting Block and carefully open Carbonated
Water Shut-off Valve. If little or no Carbonated
Water is present, Mounting Block is restricted.
Remove and clean mounting block. Replace if
necessary.
Readjust Flow Control to proper Brix (5 oz in
4seconds Standard valve, 10 oz in 4 seconds
Fast Flow valve). If no response, clean Carbon-
ated Water Flow Control. Replace if necessary.
Clean Carbonated Water valve Port Assembly.
Replace Carbonated Water Seat.
Replace Carbonated Water Solenoid Coil.
Replaced Carbonated Water Switch.