Specifications
Multiplex Company, Inc.
Complete System Overview
00218011 Revision B (KAK) 31 July, 2000
44
Special feature
For use by serviceman only, or to temporarily
program all stations (products) in an emergency.
1. When you first enter calibration mode (by
pressing CAL pad three [3] times in less than
3 seconds), any station (product) STOP-FILL
pad can be pressed two (2) times in less than
2 seconds. The calibrate lamp will flash con-
tinuously.
2. The size pads of this station can now be cali-
brated as in steps 2 through 4 of Volume in-
structions. The times will replicate across all
stations (products). All stations and all sizes
will now have exactly the same pour times.
3. Immediately exit calibration mode by press-
ing the CAL pad once, to save changes. Cali-
bration light will go out.
Note: All valve flow rates and ratios must be
adjusted exactly the same before attempting this
"one valve adjusts all" routine.
4. Individual stations/sizes can be re-calibrated
when necessary.
Instructions for Proper Dispensing Valve
Calibration (Flow, Ratio, and Volume)
usingthe4-Size Portion Control
(continued)