Specifications
Multiplex Company, Inc.
Complete System Overview
00218011 Revision B (KAK) 31 July, 2000
6
Carbonator Pump and Motor
Function of the carbonator pump and motor
Increases the pressure of the water, to overcome the CO2 pressure and manufacture/replenish
the carbonated water supply within the carbonator tank.
Failure of the carbonator pump and motor
A weak or defective carbonator pump or motor (key) will cause poor carbonation and limit the
capacity of the unit to manufacture carbonated water.
Must have
250psi(17.2bar) relief
valve setting
Coupling
Clamp
Notes:
w Check water pressure with pumps running (10 psi [0.7 bar] minimum)
w To adjust relief valve setting, dead head to gauge (incoming water pressure + 250 relief
setting)
w Check strainer
w Check for frozen coil in water bath (water to carbonator tank coil)
w Check for power to the motor
w Make sure pump turns freely
To determine the approximate
cycle time:
1. Right after the carbonator kicks
off, draw the carbonated water
into a volume cup until the car-
bonator starts again.
2. Note how many ounces you have
and multiply by 0.28 to determine
how many seconds your cycle time
should be.
(100 GPH pump =
3.56oz/second)
Note: A unit with two 100 GPH pumps
feed the same carbonator tank, mul-
tiply by 0.14