Specifications

Multiplex Company, Inc.
Complete System Overview
00218010 Revision B (KAK) 31 July, 2000
14
Water filters
Every 4 months (3 times per year)
w Verify that incoming water pressure is not less than 40 psi (2.8 bar) or greater than 60
psi (4.1 bar). If equipped with a water regulator, verify proper setting of 55 psi (3.8 bar).
Adjust if necessary.
w If pressure is low, inspect water filter cartridges to ensure they are able to supply
adequate water pressure under normal system flow. Replace if unable to provide
minimum 20 psi (1.4 bar) under load.
Syrup supply
Daily (365 times per year)
w Clean general area of syrup hookup with soap and warm water. Rinse off all soap.
Every 4 months (3 times per year)
w Inspect syrup lines for proper flavor identification labels. Replace labels if necessary.
w Disconnect syrup containers. Clean connector with soap and warm water. Rinse with
plain water and reconnect to syrup containers.
CO
2 gas supply
Every 4 months (3 times per year)
w Inspect pressure setting at CO
2 high pressure regulator. Verify proper 90 psi (6.3 bar)
pressure setting. Adjust if necessary.
w Inspect pressure setting at syrup pressure regulators. Verify proper pressure setting.
Adjust if necessary.
w Inspect system for CO
2 leaks, repair as required.
Maintenance Schedule (continued)
Periodic maintenance for soft drink equipment (listed by major
components) (continued)