Specifications
Multiplex Company, Inc.
Illustrated Fittings and Hardware Catalog
25
00218013 Revision C (KAK) 7 August, 2000
John Guest Fittings (continued)
How to use john guest fittings
Before inserting tubing into John Guest Fitting, be sure end of tubing is cleanly cut at a 90° angle.
2. Insert tubing into John Guest Fitting. Push tub-
ing firmly through fitting until it rests against a
tube stop in the fittings main body housing. The
tubing is now automatically locked into John
Guest Fitting.
Right
Wrong
For stainless steel
Metal tubing must be cut square and have a smooth
burr-free end.
1. Turn the LOCKING CAP to show approximately
1
/8" (3mm) of thread at X.
2. Push fitting onto the STAINLESS STEELensuring
that it is fully up against the tube stop.
3. Tighten the LOCKING CAP half a turn. If the fit-
ting is not secure, tighten a little further.
4. Make sure fitting is secure.
5. Push Plastictubing into other and of fitting in-
suring that it is fully up against the tube stop.
To release the fitting from the Stainless Steeltube,
simply unscrew the LOCKING CAP three quarters of
a turn, depressing the collet head as with a
conventional John Guest Fitting.
Note: If a fitting leaks as the SUPER SEAL end,
simply tighten the LOCKING CAP until leaking stops.
By doing this you increase the compression sealing
of the O-rings on the steel tail.
Wrong Right
Tubing
Collet
Collet Cover
Tubing
Collet
Collet Cover
3. To release tubing from John guest Fitting, push
in collet located on John Guest Fitting (if neces-
sary, remove collet cover).