Location
ArcticPure® water filtration systems should be located on the
incoming cold water line and preferably away from heavy
traffic areas. The system should be mounted on a wall or
structure that will support the weight of the system when
filled with water.
Notice
This product is designed for cold water use only (less than
100°F [38°C]). Passing hot water through this product
may seriously damage filter housings and/or cartridges
and affect warranty coverage.
ArcticPure® systems may be used with metal or non-metallic
piping systems.
NOTE: Any non-metallic fittings used in the installation must
be of adequate rating for the line pressure.
Water Service
All ArcticPure® systems come with 3/8" John Guest
connections on the inlet and outlet ports.
John Guest connections are suitable for use with the
following tubing:
• Polyethylene
• Nylon
• Polyurethane
• Seamless Brass (soft)
• Seamless Copper (soft)
• Seamless Mild Steel (soft)
Notice
DO NOT use with hard metal tubing such as:
• Stainless steel
• Chrome plated copper
• Hard metal polished tubing
ASSEMBLY - AR-10000/AR-20000
NOTE: The head/bracket will be packed separately from the
filter cartridge in the product box.
1. Locate position to mount the filter system. Be sure
to leave enough clearance (a minimum of 2" [5 cm]
beneath the filter cartridge length is recommended) to
allow for cartridge changeout.
2. Mark and drill mounting holes.
3. Mount filter head, using key hole slots in the mounting
bracket.
4. Remove the protective cap from the cartridge.
5. Inspect the cartridge and o-rings for damage. See
Recommended Replacement Parts List in Section 3 if
replacement is required.
6. Lubricate o-rings with food grade lubricant.
7. With the product label facing to the left, insert the
cartridge into the filter head. Rotate 1/4 turn to the right
to secure. Product label will face forward.
ASSEMBLY - AR-40000
NOTE: The manifold cover will be packed separately from the
manifold. The filter cartridges will be packed separately in
the product box.
Locate position to mount the filter system. Be sure to leave
enough clearance (a minimum of 2" [5 cm] beneath the
filter cartridge length is recommended) to allow for cartridge
changeout.
1. Use a level under the mounting bracket to be sure that
the system hangs evenly.
2. Mark and drill the top and bottom mounting holes.
3. Install bottom mounting fasteners and mount the
manifold, using the key hole slots in the mounting
bracket.
4. Install top mounting fastener.
5. Install manifold cover, using the 4 sheet metal screws
provided.
6. Remove the protective cap from each cartridge.
7. Inspect each cartridge and all o-rings for damage. See
Recommended Replacement Parts List in Section 3 if
replacement is required.