Instructions / Assembly
Part Number: 8014623 Rev01 2/17 11
Important
Please use Troubleshooting Chart to repair system. If
system still does not work properly, contact Manitowoc
Service for assistance.
Troubleshooting Chart
Problem Cause To Correct
No water through filter system
Water to filter system shut off Turn on water supply
Filter cartridges plugged
Replace filter cartridges — See “Changing
Cartridges”
Low water flow through filter
System below 20 psi
Restore system pressure
Repair water supply to filter
Filter cartridges plugged
Replace filter cartridges — See “Changing
Cartridges”
Water leak on water inlet/outlet
Water line ends are damaged
Trim water line to remove damaged area —
See “Repairing Inlet/Outlet Connections”
O-ring in filter head is damaged Replace o-ring — See “Changing Cartridges”
Water leak between head and filter cartridge Damaged o-ring on filter cartridge Replace o-ring — See “Changing Cartridges”
Repairing Inlet/Outlet Connections
A leak may occur at the inlet/outlet connections because of
defective tubing. To repair:
1. Turn off incoming water supply and depressurize system
by removing the filter cartridge(s).
2. Disconnect the water line by pushing the collet squarely
against the face of the fitting.
3. Pull the tubing to release.
4. To repair the connection, cut off at least 3/8" (6.4 mm)
from the end of the tubing. Tubing ends must be cut
square to ensure a positive seal.
5. Refer to notes and instructions under “Installation -
AR-10000/AR-20000/AR-40000” to reconnect the water
line.
Recommended Replacement Parts List
Part Number Description
K00337 AR-Pre CartridgeAR
K00338 AR-10000 Cartridge
K00339 AR-20000 Cartridge
7601973 John Guest Collet
7601983 John Guest O-Ring
Section 3
Troubleshooting