Instructions / Assembly

10 Part Number: 8014623 Rev01 2/17
Installation Section 2
10. Inspect the cartridge and o-rings for damage. See
Recommended Replacement Parts List if replacement is
required.
,
Caution
DO NOT use petroleum jelly.
11. Lubricate o-rings with food grade lubricant.
12. With the product label facing to the left, insert the
cartridge into the filter head. Rotate 1/4 turn to the right
to secure. Product label will face forward.
Installation Checklist
Have the min.-max. water temperature and pressure
been checked? (Refer to “General”)
Has the filter system been installed away from heavy
traffic areas?
Is the system installed securely to the mounting surface?
Has the water supply line been checked for suitability?
(Refer to “Water Service”)
Have the water supply lines been securely installed into
the inlet/outlet ports? (Refer to “Installation - AR-10000/
AR-20000 & AR-40000”)
Start-Up Procedure
1. Turn on the incoming water supply.
2. Check for leaks. If the connections are leaking, refer to
the Troubleshooting section of this manual to reinstall.
NOTE: System should be flushed for 2 minutes to remove
trapped air and carbon fines (5 minutes for AR-Pre).
To set the pressure gauge:
Rotate the red follower needle clockwise until it contacts
the black pressure needle on the low side.
The red follower needle will now record the lowest water
pressure when the filter system is in use.
NOTE: The filter pressure will decrease as the cartridge life
decreases.
Changing Cartridges
ArcticPure® cartridges will need to be changed for one or
more of the following reasons:
The filter has trapped water-borne sediment and the
water flow has stopped or water pressure through the
filter has dropped below 20 psi (138 kPa).
The maximum life of the carbon filter has been reached
and the filter will no longer reduce chlorine to acceptable
levels.
The scale inhibitor has been completely dissolved and
hard scale build-up may accelerate.
It is recommended that ArcticPure® filter cartridges be
changed out:
Every 6 months or when water pressure through the
system drops below 20 psi (138 kPa), whichever occurs
first.
To change the filter:
1. Rotate the cartridge 1/4 turn to the left. The cartridge
should easily release. Dispose of used cartridge.
Important
ArcticPure® systems are equipped with internal shut-off
valves. It is not necessary to shut off the incoming water
supply during cartridge changeout.
2. Remove the protective cap from the cartridge.
3. Inspect the cartridge and o-rings for damage. See
Replacement Parts list if replacement is required.
4. Lubricate o-rings with food grade lubricant.
,
Caution
DO NOT use petroleum jelly.
5. With the product label facing to the left, insert the
cartridge into the filter head. Rotate 1/4 turn to the right
to secure. Product label will face forward.