Service manual
Replacement Procedures Section 9
9-16
Anti-Condensate Door Heater Wires
WARNING
Disconnect the electric power to the freezer before
proceeding with the following steps.
1. Remove the vinyl door breakers as described
previously.
2. Carefully, pull the heater wire connections from
the inside top corner.
3. Clip the connections, making sure to leave
enough wire length to reconnect the new heater
wire. (Figure 9.42)
4. Remove the old heater wire.
5. Starting at the inside corner, carefully place the
new heater wire around the door perimeter,
fitting it into the space between the primary
breaker retainer and the metal cabinet face.
6. Connect each end of the heater wire to the leads
in the corner.
7. Replace the breaker strips as described
previously.
Defrost Termination/Fan Delay Switch
WARNING
Disconnect the electric power to the freezer before
proceeding with the following steps.
1. Remove the evaporator-housing lid.
(Figure 9.43).
2. Locate the 3-wire defrost termination/ fan delay
switch, clamped to the suction line.
(Figure 9.44)
Continued next pageā¦
Figure 9.42
Figure 9.43
Figure 9.44