Service manual

Replacement Procedures Section 9
9-8
Digital Thermometer Display and
Probe
1. Remove the front louvered hatch cover by
lifting straight up and pulling straight out.
2. Unplug the thermometer probe from the back of
the digital display module.
3. Carefully pry the display module from the hatch
cover back with a flat blade screwdriver or
scraping tool (Figure 9.23).
4. Disconnect the (2) yellow wires from the probe
harness. Remove the probe from the interior
ceiling by loosening the mounting bracket screw
(Figure 9.24)
5. Remove the Permagum sealant from the cabinet
top where the probe wire penetrates the top.
Carefully pull the probe wire through the
cabinet top.
6. Feed the new probe wire through the top hole
and reattach the probe and bracket to the interior
ceiling.
7. Carefully, pull the wire taught and reseal the
cabinet top hole with the Permagum.
8. Peel the paper from the mounting tape on the
digital display module.
Continued next page…
Figure 9.23