User Manual

Table Of Contents
Part Number: 000014110 Rev 01 1/19 21
Section 2 Installation
3. Mount the LuminIce® and transformer
to the mounting bracket.
Mount the components on the opposite
side of the bracket lip. The bracket
lip will slide between the top rail and
insulation when mounted.
LuminIce® - The bulb and bulb wiring
must face up to allow bulb replacement
with the LuminIce® in place. Mount the
LuminIce® on the left side of the bracket.
Power supply - Mount the power supply
to the right of the LuminIce®.
4. Install mounting plate in ice machine
and secure with fasteners. The
mounting plate has pass-through holes
for the hose adapters.
5. Disconnect L1 & N wires and install L1
& N of wiring adapter to the incoming
power supply wires. Connect removed
wires and LuminIce® wires to adapter.
Wires Removed From Contactor
LuminIce® Power
Incoming
Power Supply
N
L1
6. Route transformer low voltage wiring
(black and yellow wires) to the
LuminIce®. Snap the wire harness
connectors together. Bundle and
secure any excess low voltage wires
near the transformer.
7. Cut the LuminIce® hose to length and
attach:
NOTE: The upper bulkhead adapter
connects to the upper connector on the
LuminIce® and the lower bulkhead adapter
connects to the lower LuminIce® connector.
Insert tubing onto the lower bulkhead
adapter and dry fit to establish length,
then cut to fit. Attach to LuminIce® and
secure with snap clamp.
Insert tubing onto the upper bulkhead
adapter and dry fit to establish length,
then cut to fit. Attach to LuminIce® and
secure with snap clamp.
Reinstall the evaporator dust cover.
8. Test run:
Install all panels except the front panel.
Restore power - The LuminIce® is
energized whenever power is applied to
the ice machine. A noticeable draft will
be emitted from the upper hose adapter
during operation.