User Manual
Table Of Contents
- Safety Notices
- Section 1
- Section 2
- Installation
- Indigo® NXT or Indigo® Model 22" & 30" Wide Single Evaporator Installation
- Indigo® NXT or Indigo® Model 48" Wide Single Evaporator Installation K00451 Indigo® & K00465 Indigo® NXT
- Indigo® NXT or Indigo® Two-Evaporator Ice Machine Model Installation K00434, K00451 Indigo® & K00465 Indigo® NXT
- NEO® Undercounter Model Installation
- Ice Beverage (IB) Single Evaporator Model Installation
- Installation
- Section 3
- Blank Page
18 Part Number: 000014110 Rev 01 1/19
Installation Section 2
7. Remove four screws to allow access for
low voltage wire routing.
Remove Four
Screws
8. Route low voltage wiring (black
and yellow wires) to the LuminIce®,
and snap wire harness connectors
together. Reinstall screws removed in
previous step.
9. Install the evaporator dust cover
and test run the ice machine and
LuminIce®. The LuminIce® is energized
whenever power is applied to the ice
machine. A noticeable draft will be
emitted from the upper hose adapter
during operation.
NEO® Undercounter Model
Installation
n
Warning
Disconnect power to ice machine at the
electrical disconnect. Pressing the power
button does not disconnect line voltage.
1. Disconnect all power to the ice
machine at the electrical disconnect.
2. Remove any ice from the bin, then
remove bin to allow easier access.
• On the rear of the ice machine, remove
2 screws that secure the top cover, then
remove the top cover.
• Remove two screws from the front grill,
then pull forward to remove grill.
• Remove bin drain on left side of ice
machine.
• Rotate the latches on the left and right
side of the base to release the bin.
• Disconnect the control pad wiring on the
right side from the control box.
• Slide the bin forward and remove.
Rotate latch on left and right side
and disconnect drain