Part Number: 000014110 Rev 01 1/19 17
Section 2 Installation
K00465 INDIGO® NXT MODELS LOW
VOLTAGE WIRE INSTALLATION
Step 1 Route the low voltage wiring
harness from the control board to the
LuminIce®. Install wire clip and route
wires close to evaporator bulkhead to
assure harness is away from any moving
parts, then snap wire harness connectors
together.
Step 2 Route the low voltage wiring
harness through the control box low
voltage Heyco fitting and connect to the
control board LuminIce® connector.
LuminIce® Connector
Step 3 Test run the ice machine and
LuminIce®. A noticeable draft will be
emitted from the upper hose adapter
during operation.
K00434, K00451 INDIGO® MODEL
POWER SUPPLY INSTALLATION
PROCEDURE
Step 1 Mount power supply to
evaporator bulkhead.
Step 2 Route line voltage wires (black &
white) through line voltage Heyco fitting.
Disconnect L1 & N wires and install L1 & N
of wiring adapter to the incoming power
supply wires. Connect removed wires and
LuminIce® wires to adapter.
Incoming Power Supply
LuminIce® Power
Ice Machine Power
L1
N