LuminIce® Growth Inhibitor Ice Machine Accessory Installation, Operation and Maintenance Manual , Caution Original Document Read this instruction before operating this equipment.
Safety Notices Safety Notices Read these precautions to prevent personal injury: • Read this manual thoroughly before operating, installing or performing maintenance on the equipment. Failure to follow instructions in this manual can cause property damage, injury or death. • Routine adjustments and maintenance procedures outlined in this manual are not covered by the warranty. • Proper installation, care and maintenance are essential for maximum performance and troublefree operation of your equipment.
DANGER Follow these precautions to prevent personal injury during use and maintenance of this equipment: • It is the responsibility of the equipment • Units with two power cords must be owner to perform a Personal Protective plugged into individual branch circuits. Equipment Hazard Assessment to ensure During movement, cleaning or repair it is adequate protection during maintenance necessary to unplug both power cords. procedures.
Table of Contents Safety Notices Safety Notices............................................................................3 Definitions............................................................................... 3 Section 1 General Information Section 2 Installation Compatible Ice Machine Models.................................................7 Indigo® NXT Models................................................................. 7 Indigo® Models.........................................................
Table of Contents (continued) Section 3 Maintenance Replacement Bulb Usage.......................................................... 23 LuminIce® II Indicator Lights.................................................. 23 Bulb Replacement Frequency................................................... 23 LuminIce® Reminder Setup for Indigo® NXT & Indigo® Model Ice Machines................................................................. 23 Indigo® Touchscreen Models...............................................
Section 1 General Information Compatible Ice Machine Models LuminIce® This manual covers installation of LuminIce® II models on the ice machines listed below. The LuminIce® growth inhibitor recirculates the air in the ice machine foodzone over a UV bulb. This process will inhibit the growth of common micro-organisms on all exposed foodzone surfaces. • All LuminIce® bulbs require replacement on a yearly basis.
General Information Section 1 LuminIce® Kits Ice Machine 22" & 30" Single Evaporator I0300 through I1000 48" or Dual Evaporator NEO® Models LuminIce® II LuminIce® II LuminIce® K00464 K00450 K00424 K00465 N/A K00451 K00452 K00434 K00440 NOTE: These kits are used with NOTE: These kits are Indigo® NXT control boards with a used with Indigo® built-in LuminIce® transformer. non touchscreen models. LuminIce® Replacement Bulbs NOTE: Bulbs are not interchangeable between LuminIce® versions.
Section 2 Installation Indigo® NXT or Indigo® Model 22" & 30" Wide Single Evaporator Installation 3. Assemble bracket to left-hand top rail with three provided screws. nWarning Disconnect power to ice machine at the electrical disconnect. Pressing the power button does not disconnect line voltage. 1. 2. Disconnect all power to the ice machine at the electrical disconnect.
Installation 5. Refer to picture and install LuminIce® hoses, wire clip and secure wires to clip. Install wire clip and route wires along evaporator bulkhead Section 2 K00464 & K00465 INDIGO® NXT MODELS LOW VOLTAGE WIRE INSTALLATION Power is supplied from the control board. 1. Route the low voltage wiring harness from the control board to the LuminIce®.
Section 2 Installation K00424, K00434, K00440, K00450, K00451, K00452 INDIGO® MODEL POWER SUPPLY INSTALLATION PROCEDURE 30" Model Power Supply Mounting Mount power supply on evaporator bulkhead above control box. Attach supplied wire clip and route line voltage wires through clip. Install Power Supply Attach Wire Clip 1. 2. Route low voltage wiring (black and yellow wires) to the LuminIce®.
Installation Section 2 NOTE: QuietQube models do not have open terminals on contactor. Remove two wires from contactor, install supplied electrical connector and connect wires. Wires Removed From Contactor Contactor L2 L1 LuminIce® Power 3. Test run the ice machine and LuminIce®. The LuminIce® is energized whenever power is applied to the ice machine. A noticeable draft will be emitted from the upper hose adapter during operation.
Section 2 3. Remove bracket from ice machine and assemble LuminIce®, tubing and secure with hose clamps. NOTE: Attach power supply as shown below for Indigo® models (K00451) - Indigo® NXT models (K00465) power the LuminIce® from the control board. Installation 4. Assemble bracket to ice machine.
Installation Section 2 NOTE: Proceed to the next step for your specific LuminIce® kit number. Installation varies depending on whether power for the LuminIce® is supplied by the control board or a switching power supply needs to be installed. K00465 INDIGO® NXT MODELS LOW VOLTAGE WIRE INSTALLATION Step 1 Route the low voltage wiring harness from the control board to the LuminIce®.
Section 2 Installation Wires Removed From Contactor LuminIce® Power L2 Line Voltage L1 Power Supply Step 2 Route LuminIce® hoses to evaporator and attach. • Insert hose closest to the control box in the bottom evaporator bulkhead hole. • Insert the other hose in the upper evaporator bulkhead hole. Indigo® NXT or Indigo® TwoEvaporator Ice Machine Model Installation K00434, K00451 Indigo® & K00465 Indigo® NXT nWarning Disconnect power to ice machine at the electrical disconnect.
Installation NOTE: The bulb and bulb wiring must face toward the top of the ice machine to allow bulb replacement with LuminIce® in place. 5. Section 2 6. Refer to picture and install LuminIce® hoses. Attach LuminIce® assembly to corner post with two screws. NOTE: Proceed to the next step for your specific LuminIce® kit number. Installation varies depending on whether power for the LuminIce® is supplied by the control board or a switching power supply needs to be installed.
Section 2 Installation K00465 INDIGO® NXT MODELS LOW VOLTAGE WIRE INSTALLATION Step 1 Route the low voltage wiring harness from the control board to the LuminIce®. Install wire clip and route wires close to evaporator bulkhead to assure harness is away from any moving parts, then snap wire harness connectors together. Step 2 Route the low voltage wiring harness through the control box low voltage Heyco fitting and connect to the control board LuminIce® connector.
Installation 7. Section 2 Remove four screws to allow access for low voltage wire routing. NEO® Undercounter Model Installation nWarning Disconnect power to ice machine at the electrical disconnect. Pressing the power button does not disconnect line voltage. Remove Four Screws 1. 2. • 8. Route low voltage wiring (black and yellow wires) to the LuminIce®, and snap wire harness connectors together. Reinstall screws removed in previous step.
Section 2 3. 4. • • • • • To allow access for LuminIce® tubing, the plastic caps in the bulkhead wall must be removed and discarded. The cap located behind the evaporator will fall into the water trough. Remove water trough to retrieve, then discard cap and reinstall the water trough. Assemble bracket, hoses and wires to LuminIce® module. Short hose will route to access hole behind the evaporator. Attach 90 degree elbow to one end and attach other end to LuminIce®.
Installation 7. Route and secure line voltage wires (black & white) with the power cord. Wires must enter control box through line voltage Heyco fitting and attach to L1 and L2 contactor terminals. Section 2 Ice Beverage (IB) Single Evaporator Model Installation nWarning Disconnect power to ice machine at the electrical disconnect. Pressing the power button does not disconnect line voltage. 1. 2. • • Connect to L1 & L2 of Contactor • • 8.
Section 2 3. • • • 4. Mount the LuminIce® and transformer to the mounting bracket. Mount the components on the opposite side of the bracket lip. The bracket lip will slide between the top rail and insulation when mounted. LuminIce® - The bulb and bulb wiring must face up to allow bulb replacement with the LuminIce® in place. Mount the LuminIce® on the left side of the bracket. Power supply - Mount the power supply to the right of the LuminIce®.
Installation Section 2 THIS PAGE INTENTIONALLY LEFT BLANK 22 Part Number: 000014110 Rev 01 1/19
Section 3 Maintenance Replacement Bulb Usage Replacement bulbs are not interchangeable between LuminIce® and LuminIce® II. • LuminIce® replacement bulb - K00425 • LuminIce® II replacement bulb - K00454 LUMINICE® II INDICATOR LIGHTS LuminIce® II has an LED light for status indication: • Steady red light = Replace bulb • Flashing red light = Service is required • Blue = Normal operation • Red/Blue flash = Incorrect replacement bulb has been installed.
Maintenance Section 3 Bulb Replacement 5. Remove retainer from old bulb and install on replacement bulb. 6. Align slot on LuminIce® and notch on retainer and install replacement bulb in LuminIce®. 7. Insert bulb until it seats in the retainer stop on the opposite end. nWarning Disconnect power to ice machine at the electrical disconnect. Pressing the power button does not disconnect line voltage. 1. 2. 3. 4. 24 Disconnect all power to the ice machine at the electrical disconnect.
Section 3 8. Attach connector to bulb. 9. Reinstall panels and reapply power The LuminIce® is energized whenever power is applied to the ice machine. 10. Dispose of the old bulb - The bulb contains mercury, like other fluorescent and CFL bulbs and is disposed in the same manner. Refer to epa.gov for information on recycling requirements and locations in your area.
Maintenance BEFORE CLEANUP • Have people and pets leave the room, and avoid the breakage area on the way out. • Open a window or door to the outdoors and leave the room open for 5 - 10 minutes. • Shut off the central forced air heating/air conditioning (H&AC) system. • Collect materials you will need to clean up the broken bulb: A. Stiff paper or cardboard B. Sticky tape (e.g., duct tape) C. Damp paper towels or disposable wet wipes (for hard surfaces) D.
Section 3 If vacuuming is needed to ensure removal of all broken glass, keep the following tips in mind: • Keep a window or door to the outdoors open. • Vacuum the area where the bulb was broken using the vacuum hose, if available; and remove the vacuum bag (or empty and wipe the canister) and seal the bag/vacuum debris, and any materials used to clean the vacuum, in a plastic bag.
Maintenance If vacuuming is needed to ensure removal of all broken glass, keep the following tips in mind: • Keep a window or door to the outdoors open. • Vacuum the area where the bulb was broken using the vacuum hose, if available; and remove the vacuum bag (or empty and wipe the canister) and seal the bag/vacuum debris, and any materials used to clean the vacuum, in a plastic bag.
MANITOWOC ICE 2110 SOUTH 26TH STREET MANITOWOC, WI 54220 844-724-2273 WWW.MANITOWOCICE.COM WWW.WELBILT.COM Welbilt provides the world’s top chefs, and premier chain operators or growing independents with industry leading equipment and solutions. Our cuttingedge designs and lean manufacturing tactics are powered by deep knowledge, operator insights, and culinary expertise. All of our products are backed by KitchenCare® – our aftermarket, repair, and parts service.