User Manual

Section 2 Installation Instructions
Part Number 000008463 Rev01 4/15 11
7. Route line voltage wires (Black & White) through line
voltage Heyco fitting. Disconnect LI & N wires and
install L1 & N of wiring adapter to the incoming
power supply wires. Connect removed wires and
LuminIce™ wires to adapter.
8. Remove four screws to allow access for low voltage
wire routing.
9. Route low voltage wiring (black and yellow wires) to
the LuminIce™, and snap wire harness connectors
together. Reinstall screws removed in previous step.
10. Refer to picture and install LuminIce™ hoses.
LuminIce™ Power
L1
N
Ice Machine Power
Incoming Power Supply
Remove four screws