Spec Sheet

Welbilt reserves the right to make changes to the design or specications without prior notice.
Vertical Discharge Remote Condenser
for Indigo® NXT™ Series Ice Cube Machines with R410A refrigerant
Typical Installation
Optional
34.00"
(86.36 cm)
or
38.00"
(76.20 cm)
24.50" (62.23 cm)
28.00" (71.12 cm)
29.16" (74.06 cm)
Electrica
l
Entranc
e
Discharg
e
Refrig.
Line
Liquid
Refrig.
Line
A
B
C
E
F
D
6.00" (15.24 cm)
3.50" (8.89 cm)
3.88" (9.85 cm)
12.13" (30.81 cm)
1.50" (3.81 cm)
6.50" 16.51 cm)
Optional
20.00" (50.80 c
m)
16.00" (40.64 c
m)
G
G
E
F
C
D
A
B
JCT0500 and JCT1200 Remote Condenser
Op
tional
38.
00" (96.52 cm)
34.
00" (86.36 cm)
29.50" (74.93 cm)
27.94" (70.96 cm)
Electrica
l
Entranc
e
Discharg
e
Refrig.
Line
Liquid
Refrig.
Line
29.16" 74.06 cm)
A
B
C
D
6.00" (15.24 cm)
3.50" (8.89 cm)
4.00" (10.16 cm)
14.62" (37.13 cm)
E
F
Optional
20.00" (50.80 cm)
16.00" (40.64 cm)
G
E
F
C
D
A
B
1.50" (3.81 cm)
6.50" (16.51 cm)
G
JCT1500 Remote Condenser
Electric
Electrical power to the remote condenser is intended to be
supplied from the ice machine; however, if necessary, a separate
electrical power source can be used.
Remote Indigo NXT Series Ice Machine
Indigo NXT Series Remote Condensers
with R410A Refrigerant
Standard Interconnecting Refrigerant Lines
Indigo
Model
Electrical
Service*
Minimum Circuit
Ampacity
Maximum
Fuse size
iT0500N 115/60/1 13.7 20
iT1200N 208-230/60/1 10 9.5 15 15
iT1500N 208-230/60/1 14 11.3 25 20
iT1900N 208-230/60/1 17 13 25 20
* Shaded box indicates 3 phase. Consult factory.
HACR circuit breakers can be used in place of fuses.
Condenser
Indigo
Model
Matching
Ice Machine
Condenser
Electrical
Service*
Amperage
Weight
lbs. kgs.
JCT0500 iT0500N 115/60/1 1.82 64 29
JCT1200 iT1200N 208-230/60/1 1.0 67 30
JCT1500
iT1500N,
iT1900N
208-230/60/1 1.0 69 31
* Consult factory. HACR circuit breakers can be used in
place of fuses.
Model
Line Length Weight
ft. m. lbs. kgs
R(*)-20-R-410A 20 6.07 10 4.54
R(*)-35-R-410A 35 10.67 15 6.8
R(*)-50-R-410A 50 15.24 22 9.98
*RT prefix for iT0500N and iT1200N . Order line sets separately.
*RL prefix for iT1500N and iT1900N. Order line sets separately.
The line sets above are pre-charged and come with quick connect ttings.
www.manitowocice.com
6443 01/18
2110 South 26th Street
Manitowoc, WI 54220
Tel: 1.920.682.0161
Fax: 1.920.683.7589