Service manual
80
Installation and Service Manual
WIRING DIAGRAMS
L1
L2
Fan
Motor
Fan Cycle
Control
See Note 1
Fan
Motor
K9-RC, K12-RC, and K18-RC - Remote Condensers
208/230 Volt; 60 HZ Single Phase - MODELS:K9-RCA-A; K12-RCA-A; K18-RCA-A
Export - 200 Volt; 50 HZ; Single Phase - MODELS: (see above)
Export - 220/240 Volt; 50 HZ; Single Phase - MODELS: K9-RCD-A; K12-RCD-A; K18-RCD-A
NOTE: Check Serial Tag for Correct Voltage
NOTES:
1. K9-RC uses only one fan motor.
2. L1 and L2 going to remote condenser will be wired directly to electrical service through a disconnect box.