WARRANTY INFORMATION
SERVEND MODEL NUMBERING SYSTEM
Example:
MODEL- C 7 - A M A S - A A
(1) (2) (3) (4) (5) (6) (7) (8)
(1) Series of the machine
C = 30" or 48" wide cuber
S = 22" wide cuber
B = Ice Storage Bin
(2) Nominal Capacity per twenty four hours in one hundred pounds
I.E. 7 = Seven Hundred Pounds
(3) Type of Condenser
A = Air Cooled
W = Water Cooled
R = Remote Cooled
(4) Size of Cube
M = Mini Cube (3/8" x 7/8" x 7/8")
F = Full Cube (7/8" x 7/8" x 7/8")
J = Jumbo Cube (7/8" x 7/8" x 1 1/2")
(5) Electric Code
Volts Cycle Phase
A = 208/230; 200 60; 50 1
B = 115 60 1
C = 208/230; 200 60; 50 1
D = 220/240 50 1
F = 208/230 60 1
G = 208/230 60 3
H = 220/240 50 3
(6) S = Stainless Steel Panels
(Blank) = Painted Panels
P = Painted Panels
(7) Generation Code
A, B, C, etc.....
(8) Unit Configuration
A = Standard Machine
Any Other Letter = Special Machine, call factory for parts or service information.