Service manual

60
Installation and Service Manual
OPERATING SPECS AND CHARACTERISTICS
COMPONENT SPECIFICATIONS
PART NAME MODEL
NO.
VOLTAGE/HZ OHM VALUE WATTAGE
Hot Gas Valve Coil
Fan Motor
Remote Condenser Fan
Motors (All Styles)
Pump Motor
C2/C4 - S2/S4
C7/C9
C2/C4 - S2/S4
C12
C2 - S2
C4 - S4
C7/C12
C9
All Styles
C2/C4 - S2/S4
C7/C9/C12
120 VAC - 50/60 HZ
208/230 VAC 50/60 HZ
208/230 VAC
208/230 VAC - 50/60 HZ
110 VAC - 60 HZ
220/240 VAC - 50 HZ
115 VAC - 60 HZ
220/240 VAC - 50 HZ
208/230 VAC - 60 HZ
208/230 VAC - 60 HZ
208/230 VAC - 50 HZ
208/230 VAC - 60 HZ
208/230 VAC - 50 HZ
208/230 - 60 HZ
110 VAC - 50/60 HZ
208/230 - 50/60 HZ
1430
545
545
545
31
104
71
16
16
47
70
31
55
31
19.4 +/- 5%
N/A
N/A
N/A
N/A
9 WATTS
9 WATTS
25 WATTS
18.3 WATTS
18.3 WATTS
35 WATTS
35 WATTS
50 WATTS
50 WATTS
50 WATTS
N/A
CONTROL CUT OUT CUT IN STANDARD SETTING
Thermo-Disc
Pump Down Control
Hi Pressure Cut-Out
Older Units
Fan Cycling Control
(Obsolete)
Current
Head Master Control
120
o
F (40
o
C)
13 PSI (.90 Bars)
450 PSI (31.03 Bars)
400 PSI (27.58 Bars)
150 PSI (10.34 Bars)
180 PSI (12.4 Bars)
N/A
95
o
F (35
o
C)
45 PSI (3.10 Bars)
225 PSI (15.51 Bars)
250 PSI (17.2 Bars)
N/A 180 PSI (12.41 Bars)