Service manual
18
Installation and Service Manual
INSTALLATION
WATER CURTAIN ADJUSTMENT
The water curtain acts as a shield to prevent the
water circulated across the evaporator from teh splash-
ing into the bin, resulting in additional make up water
being required.
To adjust, the screws holding the curtain bracket and
pin assembly must be loosened, left and right side. The
bracket assembly will allow the curtain to be adjusted
5/16" (8mm) up or down and front to rear. the bottom
edge of the curtain should be set to clear the water pan
by a maximum of 1/8" (.32cm). Normal adjustment, front
to rear, would be to adjust the curtain in as far as pos-
sible.
Adjustment must also observe side to side travel of
curtain. Any side to side movement of 1/16" (.16cm) or
greater must be shimmed out as this would create er-
ratic operation of proximity and/or Hall switch.
NOTE: Be certain water pan is properly seated on
it's support blocks
before adjusting water curtain.