Service manual
15
Installation and Service Manual
INSTALLATION
ADJUSTING PROPER WATER LEVEL
Siphon System:
A) Be sure water pan is properly seated on its sup-
port blocks.
B) Adjust float by releasing the bracket screws to
raise, or lower, float assembly.
C) Water level should be set 3/8" (.95cm) below the
bottom of siphon hose clip.
D) With water level set, turn pump on to circulate
the water. Be sure the float will return water level to origi-
nal setting and stops inlet water.
E) Turn water pump off. The machine should now
siphon, the siphon action stops and the float returns the
water level to original settings.
F) The flow washer in the float assembly (detail A)
will control water pressure from 55/120 PSI (3.79/8.27
Bars) to eliminate float chatter. In low water areas 20
PSI (1.37 Bars) and less, remove the flow washer.
Dump System:
A) Adjust float by disengaging the bracket screws
to raise, or lower, float assembly.
B) Water level to be set at water level mark on wa-
ter pan (see diagram).
C) With water level set, turn water pump ON to cir-
culate the water. Examine to be sure the float will return
water level to original setting and stops inlet water.
D) Depress and hold the manual dump switch (white
button by toggle switch) - allow dump action to empty
water pan. This is a momentary switch - you must hold it
depressed to complete manual dump cycle.
E) Release the manual dump switch - float should
return water to original level.