User Manual
Table Of Contents
40  Part Number 000014141 Rev 07 2/20
Operation  Section 3
Safe Operation Mode
Allows the ice machine to operate up to 
72 hours if the ice thickness probe and/or 
water level probe sensors fail.
•  When the control board starts the safe 
mode, an alert is flashed on the display 
to notify the end-user they have a 
production problem.
•  The control board automatically initiates 
and monitors the safe mode. The control 
will automatically exit the safe mode if a 
normal signal is received from the input. 
•  After 72 hours, the control board will 
enter a standby mode and turn off.
NOTE: The control board needs a five cycle 
history to operate safe mode. If five cycles 
have never been successfully completed 
the ice machine will shut-off.
Water Assist Harvest
When the damper/curtain does not open 
within 3.5 minutes in the harvest cycle the 
following occurs:
•  3.5 minutes - The water inlet valve 
energizes until water touches the high 
water level probe.
•  4 minutes - The water pump energizes.
•  6.5 to 7 minutes - The water dump valve 
energizes.
Water Thaw Cycle
When the damper/curtain does not open 
during the 7 minute harvest cycle the 
following water thaw cycle occurs:
•  7 minutes - The compressor, harvest 
solenoid valve and dump valve de-
energize.
1.  The water pump remains energized 
and the water inlet valve energizes 
until water touches the high water 
level probe.
2.  Water is circulated over the 
evaporator. 
3.  Water is circulated, dumped and 
refilled to the high water level probe 
for approximately 1 hour.
•  At the end of the thaw cycle the ice 
machine will start another freeze cycle 
(approximately 1 - 1.75 hour).