Service Manual
Table Of Contents
- Safety Notices- Definitions
- General Information
- Installation
- Maintenance
- Operation
- Troubleshooting- Troubleshooting
- Troubleshooting By Symptom- Reset To Factory Defaults
- Symptom #1 - Ice Machine Will Not Run
- #2 - Low Production, Long Freeze Cycle
- Symptom #2 - Freeze Cycle Refrigeration System Operational Analysis Tables
- Symptom #3 & #4 - Harvest Problems Self‑contained Air, Water & Remote Condenser Models
- Symptom #3 - Self-Contained Air or Water-cooled
- Symptom #3 - Remote Condenser
- Symptom #4 - Self-Contained Air, Water-Cooled or Remote
 
 
- Component Check Procedures- Electrical Components- Control Board, Display And Touchscreen
- Control Board Relay Test
- Programming A Replacement Control Board
- USB Flash Drive Specifications and Formatting
- Exporting Data to a Flash Drive
- Upgrading Firmware with a Flash Drive
- Main Fuse
- Bin Switch
- Water Level Control Circuitry
- Ice Thickness Probe (Initiates Harvest)
- Bin Level Probe
- Thermistors
- High Pressure Cutout (HPCO) Control
- Fan Cycle Control
- Harvest Assist Air Pump
- Compressor Electrical Diagnostics
- Diagnosing Start Components
 
- Refrigeration Components
- Refrigerant Recovery/Evacuation
- System Contamination Clean-Up
- Liquid Line Filter-Driers
- Replacing Pressure Controls Without Removing Refrigerant Charge
- Total System Refrigerant Charge
 
- Electrical Components
- Charts
- Diagrams- Wiring Diagrams- Wiring Diagram Legend
- IF0300/IT0420/IT0450/IT0500/IT0620/IT0750 1ph Air/Water
- IT0500/IT1200 - 1ph Remote Air-Cooled
- IF0600/IF0900/IT0900/IT1200 - 1ph Air/Water
- IF0600/IF0900/IT0900/IT1200 - 3ph Air/Water
- IT1500/IT1900 - 1ph Air/Water
- IT1500/IT1900 - 3 ph Air/Water
- IF0500/IF0600/IF0900/IT1200/IF1500 - 1ph Remote
- IF0500/IF0600/IF0900/IT1200/IF1500 - 3ph Remote Condenser
 
- Electronic Control Board
- Refrigeration Tubing Schematics
 
- Wiring Diagrams
 
Part Number: 000015430 Rev 02 5/20 97
Ice Machine has a Long Freeze Cycle 
   Ice Formation is Thick 
or 
Thin on Inlet or Outlet of Evaporator 
or 
Low Production
How to Use the Freeze Cycle Refrigeration System 
Operational Analysis Table
GENERAL
These tables must be used with charts, checklists and 
other references to eliminate refrigeration components 
not listed on the tables and external items and problems 
which can cause good refrigeration components to appear 
defective.
The tables list five different defects that may affect the ice 
machine’s operation.
NOTE: A low-on-charge ice machine and a starving 
expansion valve have very similar characteristics and are 
listed under the same column.
NOTE: Before starting, see “Before Beginning Service” for 
a few questions to ask when talking to the ice machine 
owner.
PROCEDURE
Step 1  Complete the “Operation Analysis” column.
Read down the left “Operational Analysis” column. 
Perform all procedures and check all information listed. 
Each item in this column has supporting reference material 
to help analyze each step.
While analyzing each item separately, you may find an 
“external problem” causing a good refrigerant component 
to appear bad. Correct problems as they are found. If 
the operational problem is found, it is not necessary to 
complete the remaining procedures.