Service Manual
Table Of Contents
- Safety Notices- Definitions
- General Information
- Installation
- Maintenance
- Operation
- Troubleshooting- Troubleshooting
- Troubleshooting By Symptom- Reset To Factory Defaults
- Symptom #1 - Ice Machine Will Not Run
- #2 - Low Production, Long Freeze Cycle
- Symptom #2 - Freeze Cycle Refrigeration System Operational Analysis Tables
- Symptom #3 & #4 - Harvest Problems Self‑contained Air, Water & Remote Condenser Models
- Symptom #3 - Self-Contained Air or Water-cooled
- Symptom #3 - Remote Condenser
- Symptom #4 - Self-Contained Air, Water-Cooled or Remote
 
 
- Component Check Procedures- Electrical Components- Control Board, Display And Touchscreen
- Control Board Relay Test
- Programming A Replacement Control Board
- USB Flash Drive Specifications and Formatting
- Exporting Data to a Flash Drive
- Upgrading Firmware with a Flash Drive
- Main Fuse
- Bin Switch
- Water Level Control Circuitry
- Ice Thickness Probe (Initiates Harvest)
- Bin Level Probe
- Thermistors
- High Pressure Cutout (HPCO) Control
- Fan Cycle Control
- Harvest Assist Air Pump
- Compressor Electrical Diagnostics
- Diagnosing Start Components
 
- Refrigeration Components
- Refrigerant Recovery/Evacuation
- System Contamination Clean-Up
- Liquid Line Filter-Driers
- Replacing Pressure Controls Without Removing Refrigerant Charge
- Total System Refrigerant Charge
 
- Electrical Components
- Charts
- Diagrams- Wiring Diagrams- Wiring Diagram Legend
- IF0300/IT0420/IT0450/IT0500/IT0620/IT0750 1ph Air/Water
- IT0500/IT1200 - 1ph Remote Air-Cooled
- IF0600/IF0900/IT0900/IT1200 - 1ph Air/Water
- IF0600/IF0900/IT0900/IT1200 - 3ph Air/Water
- IT1500/IT1900 - 1ph Air/Water
- IT1500/IT1900 - 3 ph Air/Water
- IF0500/IF0600/IF0900/IT1200/IF1500 - 1ph Remote
- IF0500/IF0600/IF0900/IT1200/IF1500 - 3ph Remote Condenser
 
- Electronic Control Board
- Refrigeration Tubing Schematics
 
- Wiring Diagrams
 
138  Part Number: 000015430 Rev 02 5/20
CONTROL BOARD RELAY TEST
The control board can be set to energize all relays for 3.5 
minutes. This allows testing to verify control board relays 
are closed and line voltage is available for ice machine 
components - Water pump, dump valve, water inlet valve, 
harvest valve(s), air compressor(s), contactor/compressor/
fan motor - The fan cycle control must close to energize 
the fan motor.
1.  Press On/Off button to turn off ice machine and 
navigate in menu to enable all relays.
•  Menu/Service/Diagnostics/Control Board/Enable All 
Relays.
2.  The control board will energize all relays and the red 
light next to the relay. The red light indicates the relay 
coil is energized.
3.  Test for line voltage at the individual components.
A.  Line voltage is present and the component is non 
functional - Replace component
B.  Voltage is not present at the component - 
Proceed to step 5
4.  Refer to wiring diagram and determine wire location 
on the 9 pin molex connector for the component you 
are testing.
5.  Check for line voltage at the control board 9 pin molex 
connector.
A.  Line voltage at 9 pin connector - Repair wiring to 
component
B.  No power at 9 pin connector - Replace control 
board










