User Manual
Table Of Contents
52  Part Number 000014141 Rev 07 2/20
Troubleshooting  Section 5
Problem Possible Cause To Correct
Ice machine does not cycle 
into harvest mode.
The six-minute freeze time 
lock-in has not expired yet.
Wait for the freeze lock-in to 
expire.
Ice thickness probe is dirty. Descale and sanitize the ice 
machine. (See page 43)
Ice thickness probe is 
disconnected.
Connect the probe to the 
control board.
Ice thickness probe is out of 
adjustment.
Adjust the ice thickness probe. 
(See page 41)
Uneven ice fill (thin at the top 
of evaporator).
Verify sufficient water level 
in sump trough. Contact a 
qualified service company to 
check refrigeration system.
Ice quality is poor (soft or 
not clear).
Poor incoming water quality. Contact a qualified service 
company to test the quality 
of the incoming water and 
make appropriate filter 
recommendations.
Water filtration is poor. Replace the filter.
Ice machine is dirty. Descale and sanitize the ice 
machine. (See page 43)
Water dump valve is not 
working.
Disassemble and clean the 
water dump valve.
Water softener is working 
improperly (if applicable).
Repair the water softener.
Ice machine produces 
shallow or incomplete 
cubes, or the ice fill 
pattern on the evaporator 
is incomplete.
Ice thickness probe is out of 
adjustment.
Adjust the ice thickness probe. 
(See page 41)
Water trough level is too low. Check the water level probe 
position.
Water inlet valve filter screen 
is dirty.
Remove the water inlet valve 
and clean the filter screen.
Water filtration is poor. Replace the filter.
Hot incoming water. Connect the ice machine to a 
cold water supply. (See page 
22)
Water inlet valve is not 
working.
Replace the water inlet valve. 
Incorrect incoming water 
pressure.
Water pressure must be 
20 psi - 80 psi 
(140 kPa - 550 kPa).
Ice machine is not level. Level the ice machine.