Service Manual
Table Of Contents
- Safety Notices- Definitions
- General Information
- Installation
- Maintenance
- Operation
- Troubleshooting- Troubleshooting
- Troubleshooting By Symptom- Reset To Factory Defaults
- Symptom #1 - Ice Machine Will Not Run
- #2 - Low Production, Long Freeze Cycle
- Symptom #2 - Freeze Cycle Refrigeration System Operational Analysis Tables
- Symptom #3 & #4 - Harvest Problems Self‑contained Air, Water & Remote Condenser Models
- Symptom #3 - Self-Contained Air or Water-cooled
- Symptom #3 - Remote Condenser
- Symptom #4 - Self-Contained Air, Water-Cooled or Remote
 
 
- Component Check Procedures- Electrical Components- Control Board, Display And Touchscreen
- Control Board Relay Test
- Programming A Replacement Control Board
- USB Flash Drive Specifications and Formatting
- Exporting Data to a Flash Drive
- Upgrading Firmware with a Flash Drive
- Main Fuse
- Bin Switch
- Water Level Control Circuitry
- Ice Thickness Probe (Initiates Harvest)
- Bin Level Probe
- Thermistors
- High Pressure Cutout (HPCO) Control
- Fan Cycle Control
- Harvest Assist Air Pump
- Compressor Electrical Diagnostics
- Diagnosing Start Components
 
- Refrigeration Components
- Refrigerant Recovery/Evacuation
- System Contamination Clean-Up
- Liquid Line Filter-Driers
- Replacing Pressure Controls Without Removing Refrigerant Charge
- Total System Refrigerant Charge
 
- Electrical Components
- Charts
- Diagrams- Wiring Diagrams- Wiring Diagram Legend
- IF0300/IT0420/IT0450/IT0500/IT0620/IT0750 1ph Air/Water
- IT0500/IT1200 - 1ph Remote Air-Cooled
- IF0600/IF0900/IT0900/IT1200 - 1ph Air/Water
- IF0600/IF0900/IT0900/IT1200 - 3ph Air/Water
- IT1500/IT1900 - 1ph Air/Water
- IT1500/IT1900 - 3 ph Air/Water
- IF0500/IF0600/IF0900/IT1200/IF1500 - 1ph Remote
- IF0500/IF0600/IF0900/IT1200/IF1500 - 3ph Remote Condenser
 
- Electronic Control Board
- Refrigeration Tubing Schematics
 
- Wiring Diagrams
 
110  Part Number: 000015430 Rev 02 5/20
Ice Formation Pattern
Evaporator ice formation pattern analysis is helpful in ice 
machine diagnostics.
Analyzing the ice formation pattern alone cannot diagnose 
an ice machine malfunction. However, when this analysis 
is used along with Manitowoc’s Freeze Cycle Refrigeration 
System Operational Analysis Tables, it can help diagnose an 
ice machine malfunction.
Any number of problems can cause improper ice 
formation.
Important
Keep the water curtain/ice dampers in place while 
checking the ice formation pattern to ensure no water 
is lost.
1.  Normal Ice Formation
Ice forms across the entire evaporator surface.
At the beginning of the Freeze cycle, it may appear that 
more ice is forming on the inlet of the evaporator than on 
the outlet. At the end of the Freeze cycle, ice formation 
at the outlet will be close to, or just a bit thinner than, 
ice formation at the inlet. The dimples in the cubes at the 
outlet of the evaporator may be more pronounced than 
those on the inlet. This is normal.
It is normal for ice thickness to vary up to 1/16" across the 
surface of the evaporator. The ice bridge thickness at the 
ice thickness control probe should be at least 1/8".
The ice thickness probe must be set to maintain the 
ice bridge thickness at approximately 1/8" If ice forms 
uniformly across the evaporator surface, but does not 
reach 1/8" in the proper amount of time, this is still 
considered a normal ice fill pattern.