Before Calling for Service Checklist
If a problem arises during operation of your ice machine, follow the checklist below before 
calling service. Routine adjustments and maintenance procedures are not covered by the 
warranty.
Problem Possible Cause To Correct
Ice machine does not 
operate.
No electrical power to the ice 
machine and/or condensing 
unit.
Replace the fuse/reset the 
breaker/turn on the main 
switch.
High pressure cutout tripping. Clean condenser coil. (See 
page 49)
Energy Saver or other field 
entered programming is 
stopping ice machine.
Reset to factory defaults. 
Water curtain off or stuck 
open.
Water curtain must be 
installed and swinging freely.
Ice machine is not turned on.  Press power button, display 
must indicate “Making Ice”.
IB Models Only - Dispenser ice 
level thermostat is open.
Adjust thermostat to maintain 
correct dispenser level.
Ice machine stops, and can 
be restarted by pressing 
the power switch.
Service Fault feature stopping 
the ice machine.
Refer to “Service Faults” on 
page 53.
Ice machine does not 
release ice or is slow to 
harvest.
Ice machine is dirty. Descale and sanitize the ice 
machine. (See page 43)
Ice machine is not level. Level the ice machine.
Low air temperature around 
ice machine head section.
Air temperature must be at 
least 35° (2°C).
Fan cycle control does not de-
energize condenser fan motor.
Call for service.
Water regulating valve 
incorrectly adjusted or will not 
close.
Check for water at condenser 
drain outlet in harvest cycle. 
Contact a qualified service 
company to adjust/replace 
valve if water is present.
Section 5