Part Number 000014141 Rev 07 2/20  19
Section 2  Installation
Maximum Breaker Size & Minimum Circuit Amperage Chart
NOTE: Due to continuous product improvements, this information is for reference only. 
Please refer to the ice machine data plate to verify electrical data. Model/Serial data plate 
information overrides information listed on this page.
Ice 
Machine
Voltage/Phase/
Cycle
Air-Cooled Water-Cooled Remote Condenser
Maximum 
Fuse/Circuit 
Breaker
Minimum 
Circuit 
Amps
Maximum 
Fuse/Circuit 
Breaker
Minimum 
Circuit 
Amps
Maximum 
Fuse/Circuit 
Breaker
Minimum 
Circuit 
Amps
IF0300
115/1/60 15 10.8 15 10.0 - - - - - -
230/1/50 15 6.1 15 5.6 - - - - - -
230/1/60 15 6.1 15 5.7 - - - - - -
IT0300
115/1/60 15 8.8 15 7.9 - - - - - -
230/1/50 15 4.2 15 3.8 - - - - - -
230/1/60 15 4.2 15 3.8 - - - - - -
IT0420
115/1/60 15 11.3 15 10.6 - - - - - -
208-230/1/60 15 5.5 15 5.2 - - - - - -
230/1/50 15 5.7 - - - - - - - - - - - -
IT0450
115/1/60 20 11.9 20 11.2 - - - - - -
208-230/1/60 15 5.6 15 5.3 - - - - - -
230/1/50 15 5.6 15 5.3 - - - - - -
IT0500
115/1/60 15 11.5 15 10.8 20
13.7
¹14.8
208-230/1/60 15 5.1 15 4.8 - - - - - -
230/1/50 15 5.6 - - - - - - - - - - - -
IF0500
115/1/60 - - - - - - - - - - - - 20 14.8
208-230/1/60 - - - - - - - - - - - - 15 11.7
IP0500
115/1/60 15 ¹11.5 - - - - - - - - - - - -
208-230/1/60 15 ¹5.1 - - - - - - - - - - - -
230/1/50 15 ¹5.6 - - - - - - - - - - - -
IP0520
115/1/60 15 ¹11.5 - - - - - - - - - - - -
208-230/1/60 15 ¹5.1 - - - - - - - - - - - -
230/1/50 15 ¹5.6 - - - - - - - - - - - -
IF0600
208-230/1/60 15 11.1 15 10.7 15
11.7
¹8.9
230/1/50 15 6.7 15 6.1 15
7.1 
18.1
IT0620
115/1/60 20 12.2 20 11.6 - - - - - -
208-230/1/60 15 5.9 15 5.6 - - - - - -
230/1/50 15 5.6 15 5.4 - - - - - -